Paloma PH-28-C
Commercial Tankless Water Heater


(Indoor and Outdoor Models Available)

Expandable Tankless Platform
For Commercial Hot Water Systems

Model Features:

Multi-Unit System Features:

LIMITED WARRANTY
3 YEAR/Heat Exchanger
1 YEAR/Parts

Single Unit Controller

The UMC-117 Main Controller is used to set temperatures, display error codes and access maintenance information on a single unit installation.

In multi-unit systems, one Main Controller is used as the temperature controller and error display for the entire system. Others continue to be used to display diagnostic information on specific units.

One Main Controller is included with each unit.

The Main Controller can set temperatures between 100° to 180° F.

Paloma 28-C System Sizing Guide

SYSTEM
SIZE
PEAK OUTPUT
GALLONS PER MINUTE
HOURLY OUTPUT
GALLONS PER HOUR
(number of units)45 degree rise70 degree rise100 degree rise45 degree rise70 degree rise100 degree rise
17.4 gpm4.8 gpm3.4 gpm444 gallons288 gallons204 gallons
214.89.66.8888576408
322.214.410.21,332864612
429.619.213.61,7761,152816
53724172,2201,4401,020
644.428.820.42,6641,7281,224
751.833.623.83,1082,0161,428
859.238.427.23,5522,3041,632
966.643.230.63,9962,5921,836
107448344,4402,8802,040
1181.452.837.44,8843,1682,244
1288.857.640.85,3283,4562,448
1396.262.444.25,7723,7442,652
14103.667.247.66,2164,0322,856
1511172516,6604,3203,060
16118.476.854.47,1044,6083,264
17125.881.657.87,5484,8963,468
18133.286.461.27,9925,1843,672
19140.691.264.68,4365,4723,876
2014896688,8805,7604,080

How To Use The Sizing Guide

This Guide provides a quick reference to the hot water output of a system built on the 28C platform. It can help you size a system based on peak requirements in Gallons Per Minute or Gallons Per Hour.

Example 1 (see system size 4 units above): You are designing a hot water system for a shower room with six showers with 2.5 GPM flow rates, or a total system peak demand of 15 GPM. Inlet temperature in the winter is 40° F, and showering temperature is 104° F, for a rise of 64 degrees. The table shows that at a 70 degree rise, the first system above 15 GPM provides a full 19.2 GPM. Look left and see that this system consists of four 28-C units.

Example 2 (see system size 10 units above): A similar storage-based system you previously designed could deliver 2,000 gallons of 140° F hot water at maximum output. Now you want to get an initial feel for the sizing of a Paloma 28-C system that could be used instead. In your part of the country, you know that winter temperatures will require almost a 100 degree rise in water temperature to reach 140° F. So you find the Hourly Output of 2,000 Gallons in the column for 100 degree temperature rise. Then you move left to the System Size column, and read that a 10-unit system is a good starting point in the design process.

Specifications For The Paloma 28-C Series

INDOOR ModelsOUTDOOR Models
Natural Gas Model NamePH-28 CIFSNPH-28 COFN
LP Gas Model NamePH-28 CIFSPPH 28 COFP
Vent Size4" Category III stainless
venting with Paloma
stainless steel vent
adapter or equivalent
N/A
Vent Length Maximum37.5 ft. with 3 -elbowsN/A
Safety EngineeringOxygen Depletion Safety SystemsN/A
Heat Exchanger Film Wrap Overheat Limiter
Flame Failure Safety Monitor: Flame Rod Type
Anti-boil protection
Rated Gas Input (BTU/hr.)19,000 - 199,900 (modulating)
Dimensions (Inches)14-7/8 (w) x 25-3/8 (H) x 11-1/8 (D)
Net Weight (lbs.)55
Working Water Pressure14 - 150 psi
Minimum Flow for Ignition0.66 GPM
Maximum Output7.4 GPM
Temperature Range100 - 180 F (with controller)
Gas Connection3/4" NPT Female (Gas shutoff valve included)
Water Connection3/4" NPT Male
Efficiency Rating84%
Energy Factor (DOE)0.82
Electrical Requirement120 V/60Hz AC, 2 Amps
Freeze ProtectionMinus 30° F (including windchil factor)
Controller/Diagnostic DisplayUMC- 117 (included)
Multi-Unit System Controller
(sold separately)
2-6 unit system: MIC 180 (includes installation box)
7-20 unit system: MI C-180 + MI CS-180

Paloma Mic-180 Manifold Controller

The optional MIC-180 Manifold Controller is used to electronically control operations in a multi-unit system of 2 to 20 units. The MIC-180 Controller Kit includes the control logic for a base system with 2-6 units, a power cord, and an installation box suitable for outdoors.

For larger systems, add a MILS-180 Extended Communication Board, which will fit in the top half of the Installation Box.

The controller connects to the individual units using Paloma communications cables in 16, 32 and 65 foot lengths.

Prices/Orders


[ Paloma ]





[ Top of Page ]
[ Homepage ] [ Change Machines ] [ Tankless Water Heaters ] [ Washers ] [ Dryers ] [ Fluff & Fold ] [ Vending Machines ] [ Laundry Carts ] [ SiteMap ]


Last update: April 21, 2008
Webmaster, webmaster@claundry.com